Incineration solids

Incineration Solids are solid waste materials—such as contaminated debris, sludges, filters, or other non-recyclable byproducts—that are safely destroyed through high-temperature incineration. Recycling companies manage these solids to ensure the complete elimination of hazardous components, reduce landfill dependency, and protect the environment from potential contamination.

The following coditions apply to all INC prefix waste unless noted otherwise.  No  asbestos, mercury <10ppm, cyanides<500ppm, sulfides<500ppm, reactives or large pieces of metal or concrete.  Halogens less than 5%.

IS01A Soils and sludges for consolidation and incineration. Must be compatible with nearly everything and not require shredding. Free liquids ok
IS01B Light solids for consolidation and incineration Rags, pads, plastic, floor dry,vermiculite, wood, no monoliths. Max weight 250 lbs/55G including the drum. No liquids
IS01C Pesticide solids and sludge >1in solids, must not react with water or solvents. pH 4-12-5. Liquids ok
IS01D F027 Solids and sludge >1in solids, must not react with water or solvents. pH 4-12-5. Liquids ok
IS01E Acidic solids with organics Solids, pH<4 (when water added), liquids ok
IS01F Basic solids with organics Solids, pH>12.5 (when water added), liquids ok
IS02 Monolithic solids Must be shreddable. No large ieces of metal. No larger than 85G drum
IS03 Cyanides or sulfide solids pH>7 (when water added), ammonia<0.5%, liqids ok
IS04 4.1 Solids Packaged in 5gal or smaller containers.
IS05 4.2 solids Packaged in 5gal or smaller containers.
IS06 4.3 solids Packaged in 5gal or smaller containers.
IS07 Oxidizer solids Oxidizers as defined by DOT requiring incineration. Liquids ok
IS08 Organinc peroxide solids, non temp controlled Packaged in 5gal or smaller containers.
IS09 Empty containers of acutely toxic waste Otherwise empty containers that have not been triple rinsed.
IS10 Temperature controlled material Any temperature controlled material. Must be delivered in refrigerated trailer or otherwise cooled. Will be incinerated upon arrival
IS11 Debris Debris as per 40CFR268.2